Section J (Deemed to Satisfy method)
Servicing all NSW, ACT, QLD, VIC
**Contact our trusted team now for quick responses and turnaround**
Section J compliance reports provided for
Industrial Buildings
Boarding Houses, Motels / Hotels
Retail Shops
Offices / Medical Centres
Warehouses, Storage Facilities
Surgery’s, Hospitals
Day Care Centres, Schools, Educations Facilities
Commercial Spaces
ENERGY EFFICIENCY REQUIREMENTS
Classification types - Class 4, 5, 6, 7, 8, and 9 type buildings in accordance with the NCC (National Construction Code) 2019. Applies to shops, offices, bulky retail, hospitals, day care facilities, recreational facilities, medical facilities, showrooms, schools, and other commercial uses spaces.
Section J of the National Construction Code (NCC) Volume 1 requires minimum energy efficiency levels for non-residential buildings (Class 2-9) to reduce the energy needed for regular operation.
Part J.1.0 – Minimum requirements for the building fabric
Part J3.0 – Requirements to achieve compliance with sealing the building against losses and air gaps
Part 5.0 - Air-conditioning and ventilation systems requirements
Part 6.0 - Artificial lighting and power maximum requirements or limitations
Part 7.0 - Heated water supply and swimming pool and spa pool plant
Part 8.0 - Facilities for energy monitoring
MINIMUM REQUIREMENTS
Section J provides minimum requirements for each aspect of the building that affects energy use. If you can demonstrate that the minimum standards have been achieved through the design, then the structure is deemed to satisfy the requirements of section J.
WHY USE 10 STAR BUILDING ASSESSMENTS
Our assessors have experience in the construction industry and excellent knowledge of project costs. This allows us to provide recommendations that can meet compliance but use methods that reduce the construction cost of the building. If we identify that the outcome may require an alternative solution, 10 Star Building Assessments can facilitate using advanced modelling software and complete a JV3 assessment.
In our experience, this approach has contributed to construction savings, in some cases above $100k.

What should you expect?
We pride ourselves on quickly responding and meeting the client's expectations. A well-constructed Section J assessment can save you thousands of dollars during the building process, along with delivering ongoing savings across the life of a building, by using 10 Star Building Assessments. Our network of industry professionals allows us to test and confirm that our recommendations remain current with industry changes.
You will experience open dialogue and constructive suggestions and meet your timeframe restraints.